modbus-rest

1.0.3 • Public • Published

RESTful(ish) API to Modbus

Overview

Modbus is a serial communication protocol used to exchange information between electronic devices. Typically, only the modbus master in a modbus network is the one initiating communication and slaves respond to these requests. In this case, the modbus-rest acts as the master and communication (writing and reading registers) is initated through the REST API.

Running

npm install -g modbus-rest

/usr/local/bin/modbus-rest --help

/usr/local/bin/modbus-rest --serial=/dev/ttyUSB0

API

Common path parameters in the API are: unit - the slave id, address - the starting address of a read or write, quantity - the number of registers/coils to read or write.

URL Method Description
/{unit}/coil/{address} GET Reads the state of a coil.
/{unit}/coil/{address}/{quantity} GET Reads the states of multiple coils.
/{unit}/coil/{address} POST Writes a coil state. POST body should contain true or false
/{unit}/coil/{address}/{quantity} POST Writes multiple coil states. POST body should contain a JSON array of true/false
/{unit}/discrete/{address} GET Reads the state of a discrete input.
/{unit}/discrete/{address}/{quantity} GET Reads the states of multiple discrete inputs.
/{unit}/holding/{address} GET Reads the value of a holding register.
/{unit}/holding/{address}/{quantity} GET Reads the values of multiple holding registers.
/{unit}/holding/{address} POST Writes a value to a holding register. POST body should contain the value to write.
/{unit}/holding/{address}/{quantity} POST Writes values to multiple holding registers. POST body should contain the raw buffer (2 bytes per register) to write, base64 encoded.
/{unit}/input/{address} GET Reads the value of an input register.
/{unit}/input/{address}/{quantity} GET Reads the values of multiple input registers.

Query parameters

There are also a number of query parameters available:

length defines the raw register length of a value. This can be useful when a device uses more than one register to store a value.

interpreters defines transformation methods to use when reading registers, see below. Multiple interpreters can be chained by comma separation.

Interpreters

The following interpreters are supported:

raw - Do not default to any interpreter, always return raw response

integer (default for registers) - Returns an integer representation of the register value

tenths - Divide value by 10.

float32 - Interpret the input as a floating value according to IEEE-754.

float32le - Interpret the input as floating value according to IEEE-754 with little endian.