Homebridge Logo TS
!!! Homebridge-Logo-TS is deprecated, use Homebridge-Logo-Platform !!!


Use a Siemens LOGO! PLC for switch on whatever you want.
Communicate with LOGO! 8.SF4 over Modbus and with LOGO! 0BA7 / 0BA8 over Snap7.
Type of Accessory:
Type of Sensor Accessory:
Installation
- Install homebridge using:
sudo npm install -g --unsafe-perm homebridge
- Install homebridge-config-ui-x using:
sudo npm install -g --unsafe-perm homebridge-config-ui-x
- Update your configuration file with this guide: smartapfel.de
- Install homebridge-logo-ts using: homebridge-config-ui-x's Webserver (Homebridge must be started with sudo for the installation.)
- Update your configuration file with code like the sample below
Known Issues
Homebridge-Logo-TS Main Configuration Parameters
Name |
Value |
Required |
Option for |
Notes |
accessory |
"Logo-TS" |
yes |
all |
Must be set to "Logo-TS". |
name |
(custom) |
yes |
all |
Name of accessory that will appear in homekit app. |
interface |
"modbus" or "snap7" |
yes |
all |
Communication, depends on LOGO! type, 8.SF4 Modbus or Snap7, 0BA7 / 0BA8 only Snap7. |
ip |
"10.0.0.100" |
yes |
all |
Must be set to the IP of your LOGO! PLC. |
port |
505 |
no |
"modbus" |
Must be set to the Modbus Port of your LOGO! PLC, default is: 505. |
logoType |
"8.SF4" |
no |
"snap7" |
Must be set to the type of your LOGO! PLC, default is: "8.SF4". |
localTSAP |
"0x1200" |
no |
"snap7" |
Must be set to the localTSAP of your LOGO! PLC, default is: 0x1200. |
remoteTSAP |
"0x2200" |
no |
"snap7" |
Must be set to the remoteTSAP of your LOGO! PLC, default is: 0x2200. |
type |
"switch" or ... |
yes |
all |
Type of Accessory: "switch", "blind", "window", "garagedoor", "lightbulb", "thermostat", "irrigationSystem", "valve", "fan", "fanv2", "filterMaintenance", "ventilation" or Type of Sensor Accessory: "lightSensor", "motionSensor", "contactSensor", "smokeSensor", "temperatureSensor", "humiditySensor", "carbonDioxideSensor", "airQualitySensor" |
updateInterval |
0 |
no |
all |
Auto Update Interval in milliseconds, 0 = Off |
randomInterval |
1 |
no |
all |
Add a random Interval to Update Interval (0 - 10 seconds), default is: 1, -1 = Off |
buttonValue |
1 |
no |
all |
Value for Digital Button, default is: 1, -1 = 0 |
pushButton |
1 |
no |
all |
If e.g. the network input in the LOGO! a hardware button on the LOGO! simulated. default is: 1, -1 = Off |
debugMsgLog |
0 |
no |
all |
1 - Displays messages of accessories in the log. |
retryCount |
0 |
no |
all |
Retry count for sending the ModBus or Snap7 Message, default is: 0 (0 = 9 for ModBus / 5 for Snap7; -1 = Off). |
Switch Accessory Configuration
Name |
Value |
Required |
Option for |
Notes |
switchGet |
"Q1" |
yes* |
"switch" |
Switch Get - Qn, Mn or Vn.n |
switchSetOn |
"V2.0" |
yes* |
"switch" |
Switch Set On - Mn or Vn.n |
switchSetOff |
"V3.0" |
yes* |
"switch" |
Switch Set Off - Mn or Vn.n |
"accessories": [
{
"accessory": "Logo-TS",
"name": "Switch ModBus",
"interface": "modbus",
"ip": "10.0.0.100",
"port": 505,
"type": "switch",
"switchGet": "Q1",
"switchSetOn": "V2.0",
"switchSetOff": "V3.0"
},
{
"accessory": "Logo-TS",
"name": "Switch Snap7",
"interface": "snap7",
"ip": "10.0.0.200",
"logoType": "0BA7",
"localTSAP": "0x1200",
"remoteTSAP": "0x2200",
"type": "switch",
"switchGet": "Q2",
"switchSetOn": "V2.1",
"switchSetOff": "V3.1"
}
]
Blind Accessory Configuration
Name |
Value |
Required |
Option for |
Notes |
blindSetPos |
"VW50" |
yes* |
"blind" |
Blind Set Pos - AMn or VWn - (Analog Control) |
blindGetPos |
"VW52" |
yes* |
"blind" |
Blind Get Pos - AMn or VWn - (Analog Control) |
blindSetState |
"VW54" |
yes* |
"blind" |
Blind Get State - AMn or VWn - (Analog Control) |
blindDigital |
0 |
no |
"blind" |
0 for Analog Control, 1 for Button Control |
blindSetUp |
"V5.0" |
no |
"blind" |
Blind Set Up - Mn or Vn.n - (Button Control) |
blindSetDown |
"V5.1" |
no |
"blind" |
Blind Set Down - Mn or Vn.n - (Button Control) |
blindGetUpDown |
"V5.2" |
no |
"blind" |
Blind Up or Down - Mn or Vn.n - Return 1 for Up or 0 for Down - (Button Control) |
"accessories": [
{
"accessory": "Logo-TS",
"name": "Blind ModBus Analog",
"interface": "modbus",
"ip": "10.0.0.100",
"port": 505,
"type": "blind",
"blindSetPos": "VW50",
"blindGetPos": "VW52",
"blindGetState": "VW54"
},
{
"accessory": "Logo-TS",
"name": "Blind Snap7 Analog",
"interface": "snap7",
"ip": "10.0.0.200",
"logoType": "0BA7",
"localTSAP": "0x1200",
"remoteTSAP": "0x2200",
"type": "blind",
"blindSetPos": "VW50",
"blindGetPos": "VW52",
"blindGetState": "VW54"
},
{
"accessory": "Logo-TS",
"name": "Blind ModBus Digital",
"interface": "modbus",
"ip": "10.0.0.100",
"port": 505,
"type": "blind",
"blindDigital": 1,
"blindSetUp": "V5.0",
"blindSetDown": "V5.1",
"blindGetUpDown": "V5.2"
},
{
"accessory": "Logo-TS",
"name": "Blind Snap7 Digital",
"interface": "snap7",
"ip": "10.0.0.200",
"logoType": "0BA7",
"localTSAP": "0x1200",
"remoteTSAP": "0x2200",
"type": "blind",
"blindDigital": 1,
"blindSetUp": "V5.0",
"blindSetDown": "V5.1",
"blindGetUpDown": "V5.2"
}
]
Window Accessory Configuration
Name |
Value |
Required |
Option for |
Notes |
windowSetPos |
"VW50" |
yes* |
"window" |
Window Set Pos - AMn or VWn - (Analog Control) |
windowGetPos |
"VW52" |
yes* |
"window" |
Window Get Pos - AMn or VWn - (Analog Control) |
windowSetState |
"VW54" |
yes* |
"window" |
Window Get State - AMn or VWn - (Analog Control) |
windowDigital |
0 |
no |
"window" |
0 for Analog Control, 1 for Button Control |
windowSetUp |
"V5.0" |
no |
"window" |
Window Set Up - Mn or Vn.n - (Button Control) |
windowSetDown |
"V5.1" |
no |
"window" |
Window Set Down - Mn or Vn.n - (Button Control) |
windowGetUpDown |
"V5.2" |
no |
"window" |
Window Up or Down - Return 1 for Up or 0 for Down - (Button Control) |
"accessories": [
{
"accessory": "Logo-TS",
"name": "Window ModBus Analog",
"interface": "modbus",
"ip": "10.0.0.100",
"port": 505,
"type": "window",
"windowSetPos": "VW50",
"windowGetPos": "VW52",
"windowGetState": "VW54"
},
{
"accessory": "Logo-TS",
"name": "Window Snap7 Analog",
"interface": "snap7",
"ip": "10.0.0.200",
"logoType": "0BA7",
"localTSAP": "0x1200",
"remoteTSAP": "0x2200",
"type": "window",
"windowSetPos": "VW50",
"windowGetPos": "VW52",
"windowGetState": "VW54"
},
{
"accessory": "Logo-TS",
"name": "Window ModBus Digital",
"interface": "modbus",
"ip": "10.0.0.100",
"port": 505,
"type": "window",
"windowDigital": 1,
"windowSetUp": "V5.0",
"windowSetDown": "V5.1",
"windowGetUpDown": "V5.2"
},
{
"accessory": "Logo-TS",
"name": "Window Snap7 Digital",
"interface": "snap7",
"ip": "10.0.0.200",
"logoType": "0BA7",
"localTSAP": "0x1200",
"remoteTSAP": "0x2200",
"type": "window",
"windowDigital": 1,
"windowSetUp": "V5.0",
"windowSetDown": "V5.1",
"windowGetUpDown": "V5.2"
}
]
Garage Door Accessory Configuration
Name |
Value |
Required |
Option for |
Notes |
garagedoorOpen |
"V401.0" |
yes* |
"garagedoor" |
Garagedoor Open - Mn or Vn.n |
garagedoorClose |
"V401.1" |
yes* |
"garagedoor" |
Garagedoor Close - Mn or Vn.n |
garagedoorState |
"V401.2" |
yes* |
"garagedoor" |
Garagedoor State - Mn or Vn.n |
garagedoorObstruction |
"false" |
no* |
"garagedoor" |
Garagedoor Obstruction Detected - "false" or a valid LOGO! Address (Mn or Vn.n) |
"accessories": [
{
"accessory": "Logo-TS",
"name": "GarageDoor ModBus",
"interface": "modbus",
"ip": "10.0.0.100",
"port": 505,
"updateInterval": 120000,
"type": "garagedoor",
"garagedoorOpen": "V401.0",
"garagedoorClose": "V401.1",
"garagedoorState": "V401.2",
"garagedoorObstruction": "false"
},
{
"accessory": "Logo-TS",
"name": "GarageDoor Snap7",
"interface": "snap7",
"ip": "10.0.0.200",
"logoType": "0BA7",
"localTSAP": "0x1200",
"remoteTSAP": "0x2200",
"updateInterval": 120000,
"type": "garagedoor",
"garagedoorOpen": "V401.0",
"garagedoorClose": "V401.1",
"garagedoorState": "V401.2",
"garagedoorObstruction": "false"
}
]
Lightbulb Accessory Configuration
Name |
Value |
Required |
Option for |
Notes |
lightbulbSetOn |
"V7.0" |
yes* |
"lightbulb" |
Lightbulb Set On - Mn or Vn.n |
lightbulbSetOff |
"V7.1" |
yes* |
"lightbulb" |
Lightbulb Set Off - Mn or Vn.n |
lightbulbSetBrightness |
"VW70" |
yes* |
"lightbulb" |
Lightbulb Set Brightness - AMn or VWn |
lightbulbGetBrightness |
"VW72" |
yes* |
"lightbulb" |
Lightbulb Get Brightness - AMn or VWn |
"accessories": [
{
"accessory": "Logo-TS",
"name": "Lightbulb ModBus",
"interface": "modbus",
"ip": "10.0.0.100",
"port": 505,
"type": "lightbulb",
"lightbulbSetOn": "V7.0",
"lightbulbSetOff": "V7.1",
"lightbulbSetBrightness": "VW70",
"lightbulbGetBrightness": "VW72"
},
{
"accessory": "Logo-TS",
"name": "Lightbulb Snap7",
"interface": "snap7",
"ip": "10.0.0.200",
"logoType": "0BA7",
"localTSAP": "0x1200",
"remoteTSAP": "0x2200",
"type": "lightbulb",
"lightbulbSetOn": "V7.0",
"lightbulbSetOff": "V7.1",
"lightbulbSetBrightness": "VW70",
"lightbulbGetBrightness": "VW72"
}
]
Thermostat Accessory Configuration
Name |
Value |
Required |
Option for |
Notes |
thermostatGetHCState |
"VW210" |
yes* |
"thermostat" |
Thermostat Get Heating Cooling State - AMn or VWn |
thermostatSetHCState |
"VW200" |
yes* |
"thermostat" |
Thermostat Set Heating Cooling State - AMn or VWn |
thermostatGetTemp |
"VW212" |
yes* |
"thermostat" |
Thermostat Get Temperature - AMn or VWn - Current Temperature in °C (0°C - 100°C!!, a value of 105 is 10.5°C) |
thermostatGetTargetTemp |
"VW214" |
yes* |
"thermostat" |
Thermostat Get Target Temperature - AMn or VWn - Current Temperature in °C (10°C - 38°C!!, a value of 105 is 10.5°C) |
thermostatSetTargetTemp |
"VW202" |
yes* |
"thermostat" |
Thermostat Set Target Temperature - AMn or VWn |
thermostatTempDisplayUnits |
0 |
yes* |
"thermostat" |
Temperature Display Units - Celsius = 0; Fahrenheit = 1; |
"accessories": [
{
"accessory": "Logo-TS",
"name": "Thermostat ModBus",
"interface": "modbus",
"ip": "10.0.0.100",
"port": 505,
"type": "thermostat",
"thermostatGetHCState": "VW210",
"thermostatSetHCState": "VW200",
"thermostatGetTemp": "VW212",
"thermostatGetTargetTemp": "VW214",
"thermostatSetTargetTemp": "VW202",
"thermostatTempDisplayUnits": 0
},
{
"accessory": "Logo-TS",
"name": "Thermostat Snap7",
"interface": "snap7",
"ip": "10.0.0.200",
"logoType": "0BA7",
"localTSAP": "0x1200",
"remoteTSAP": "0x2200",
"type": "thermostat",
"thermostatGetHCState": "VW210",
"thermostatSetHCState": "VW200",
"thermostatGetTemp": "VW212",
"thermostatGetTargetTemp": "VW214",
"thermostatSetTargetTemp": "VW202",
"thermostatTempDisplayUnits": 0
}
]
Irrigation System Accessory Configuration
Name |
Value |
Required |
Option for |
Notes |
irrigationSystemGetActive |
"V400.0" |
yes* |
"irrigationSystem" |
Irrigation System Get Active - Mn or Vn.n |
irrigationSystemSetActiveOn |
"V400.1" |
yes* |
"irrigationSystem" |
Irrigation System Set Active to On - Mn or Vn.n |
irrigationSystemSetActiveOff |
"V400.2" |
yes* |
"irrigationSystem" |
Irrigation System Set Active to Off - Mn or Vn.n |
irrigationSystemGetProgramMode |
"VW402" |
yes* |
"irrigationSystem" |
Irrigation System Get Program Mode - AMn or VWn - (0 - No Program scheduled; 1 - Program scheduled; 2 - Program scheduled manual Mode) |
irrigationSystemGetInUse |
"V400.3" |
yes* |
"irrigationSystem" |
Irrigation System Get In Use - Mn or Vn.n |
"accessories": [
{
"accessory": "Logo-TS",
"name": "Irrigation System ModBus",
"interface": "modbus",
"ip": "10.0.0.100",
"port": 505,
"type": "irrigationSystem",
"irrigationSystemGetActive": "V400.0",
"irrigationSystemSetActiveOn": "V400.1",
"irrigationSystemSetActiveOff": "V400.2",
"irrigationSystemGetProgramMode": "VW402",
"irrigationSystemGetInUse": "V400.3"
},
{
"accessory": "Logo-TS",
"name": "Irrigation System Snap7",
"interface": "snap7",
"ip": "10.0.0.200",
"logoType": "0BA7",
"localTSAP": "0x1200",
"remoteTSAP": "0x2200",
"type": "irrigationSystem",
"irrigationSystemGetActive": "V400.0",
"irrigationSystemSetActiveOn": "V400.1",
"irrigationSystemSetActiveOff": "V400.2",
"irrigationSystemGetProgramMode": "VW402",
"irrigationSystemGetInUse": "V400.3"
}
]
Valve Accessory Configuration
Name |
Value |
Required |
Option for |
Notes |
valveGetActive |
"V400.0" |
yes* |
"valve" |
Valve Get Active - Mn or Vn.n |
valveSetActiveOn |
"V400.1" |
yes* |
"valve" |
Valve Set Active to On - Mn or Vn.n |
valveSetActiveOff |
"V400.2" |
yes* |
"valve" |
Valve Set Active to Off - Mn or Vn.n |
valveGetInUse |
"V400.3" |
yes* |
"valve" |
Valve Get In Use - Mn or Vn.n |
valveType |
0 |
yes* |
"valve" |
Valve Type - Generic Valve = 0, Irrigation = 1, Shower Head = 2, Water Faucet = 3, |
valveSetDuration |
"0" |
no* |
"valve" |
Valve Set Duration - "0" or a valid LOGO! Address (AMn or VWn) - Value in Seconds (0 - 3600 sec) |
valveGetDuration |
"0" |
no* |
"valve" |
Valve Get Remaining Duration - "0" or a valid LOGO! Address (AMn or VWn) - Value in Seconds (0 - 3600 sec) |
"accessories": [
{
"accessory": "Logo-TS",
"name": "Valve ModBus",
"interface": "modbus",
"ip": "10.0.0.100",
"port": 505,
"type": "valve",
"valveGetActive": "V400.0",
"valveSetActiveOn": "V400.1",
"valveSetActiveOff": "V400.2",
"valveGetInUse": "V400.3",
"valveType": 1,
"valveSetDuration": "0",
"valveGetDuration": "0"
},
{
"accessory": "Logo-TS",
"name": "Valve Snap7",
"interface": "snap7",
"ip": "10.0.0.200",
"logoType": "0BA7",
"localTSAP": "0x1200",
"remoteTSAP": "0x2200",
"type": "valve",
"valveGetActive": "V400.0",
"valveSetActiveOn": "V400.1",
"valveSetActiveOff": "V400.2",
"valveGetInUse": "V400.3",
"valveType": 1,
"valveSetDuration": "0",
"valveGetDuration": "0"
}
]
Fan Accessory Configuration
Name |
Value |
Required |
Option for |
Notes |
fanGetOn |
"V130.0" |
yes* |
"fan" |
Fan Get On - Mn or Vn.n |
fanSetOn |
"V130.1" |
yes* |
"fan" |
Fan Set On to On - Mn or Vn.n |
fanSetOff |
"V130.2" |
yes* |
"fan" |
Fan Set On to Off - Mn or Vn.n |
fanGetRotationDirection |
"0" |
no* |
"fan" |
Fan Get Rotation Direction - "0" or a valid LOGO! Address (Mn or Vn.n) |
fanSetRotationDirectionCW |
"0" |
no* |
"fan" |
Fan Set Rotation Direction to Clockwise - "0" or a valid LOGO! Address (Mn or Vn.n) |
fanSetRotationDirectionCCW |
"0" |
no* |
"fan" |
Fan Set Rotation Direction to Counter Clockwise - "0" or a valid LOGO! Address (Mn or Vn.n) |
fanGetRotationSpeed |
"0" |
no* |
"fan" |
Fan Get Rotation Speed - "0" or a valid LOGO! Address (AMn or VWn) |
fanSetRotationSpeed |
"0" |
no* |
"fan" |
Fan Set Rotation Speed - "0" or a valid LOGO! Address (AMn or VWn) |
"accessories": [
{
"accessory": "Logo-TS",
"name": "Fan ModBus",
"interface": "modbus",
"ip": "10.0.0.100",
"port": 505,
"type": "fan",
"fanGetOn": "V130.0",
"fanSetOn": "V130.1",
"fanSetOff": "V130.2",
"fanGetRotationDirection": "0",
"fanSetRotationDirectionCW": "0",
"fanSetRotationDirectionCCW": "0",
"fanGetRotationSpeed": "0",
"fanSetRotationSpeed": "0"
},
{
"accessory": "Logo-TS",
"name": "Fan Snap7",
"interface": "snap7",
"ip": "10.0.0.200",
"logoType": "0BA7",
"localTSAP": "0x1200",
"remoteTSAP": "0x2200",
"type": "fan",
"fanGetOn": "V130.0",
"fanSetOn": "V130.1",
"fanSetOff": "V130.2",
"fanGetRotationDirection": "0",
"fanSetRotationDirectionCW": "0",
"fanSetRotationDirectionCCW": "0",
"fanGetRotationSpeed": "0",
"fanSetRotationSpeed": "0"
}
]
Fan v2 Accessory Configuration
Name |
Value |
Required |
Option for |
Notes |
fanv2GetActive |
"V130.0" |
yes* |
"fanv2" |
Fan v2 Get Active - Mn or Vn.n |
fanv2SetActiveOn |
"V130.1" |
yes* |
"fanv2" |
Fan v2 Set Active to On - Mn or Vn.n |
fanv2SetActiveOff |
"V130.2" |
yes* |
"fanv2" |
Fan v2 Set Active to Off - Mn or Vn.n |
fanv2GetCurrentFanState |
"0" |
no* |
"fanv2" |
Fan v2 Get Current Fan State (0 = Inactive, 1 = Idle, 2 = Blowing Air) - "0" or a valid LOGO! Address (AMn or VWn) |
fanv2SetTargetFanStateAuto |
"0" |
no* |
"fanv2" |
Fan v2 Set Target Fan State to Auto - "0" or a valid LOGO! Address (Mn or Vn.n) |
fanv2SetTargetFanStateManual |
"0" |
no* |
"fanv2" |
Fan v2 Set Target Fan State to Manual - "0" or a valid LOGO! Address (Mn or Vn.n) |
fanv2GetRotationDirection |
"0" |
no* |
"fanv2" |
Fan v2 Get Rotation Direction - "0" or a valid LOGO! Address (Mn or Vn.n) |
fanv2SetRotationDirectionCW |
"0" |
no* |
"fanv2" |
Fan v2 Set Rotation Direction to Clockwise - "0" or a valid LOGO! Address (Mn or Vn.n) |
fanv2SetRotationDirectionCCW |
"0" |
no* |
"fanv2" |
Fan v2 Set Rotation Direction to Counter Clockwise - "0" or a valid LOGO! Address (Mn or Vn.n) |
fanv2GetRotationSpeed |
"0" |
no* |
"fanv2" |
Fan v2 Get Rotation Speed - "0" or a valid LOGO! Address (AMn or VWn) |
fanv2SetRotationSpeed |
"0" |
no* |
"fanv2" |
Fan v2 Set Rotation Speed - "0" or a valid LOGO! Address (AMn or VWn) |
"accessories": [
{
"accessory": "Logo-TS",
"name": "Fan v2 ModBus",
"interface": "modbus",
"ip": "10.0.0.100",
"port": 505,
"type": "fanv2",
"fanv2GetActive": "V130.0",
"fanv2SetActiveOn": "V130.1",
"fanv2SetActiveOff": "V130.2",
"fanv2GetCurrentFanState": "0",
"fanv2SetTargetFanStateAuto": "0",
"fanv2SetTargetFanStateManual": "0",
"fanv2GetRotationDirection": "0",
"fanv2SetRotationDirectionCW": "0",
"fanv2SetRotationDirectionCCW": "0",
"fanv2GetRotationSpeed": "0",
"fanv2SetRotationSpeed": "0"
},
{
"accessory": "Logo-TS",
"name": "Fan v2 Snap7",
"interface": "snap7",
"ip": "10.0.0.200",
"logoType": "0BA7",
"localTSAP": "0x1200",
"remoteTSAP": "0x2200",
"type": "fanv2",
"fanv2GetActive": "V130.0",
"fanv2SetActiveOn": "V130.1",
"fanv2SetActiveOff": "V130.2",
"fanv2GetCurrentFanState": "0",
"fanv2SetTargetFanStateAuto": "0",
"fanv2SetTargetFanStateManual": "0",
"fanv2GetRotationDirection": "0",
"fanv2SetRotationDirectionCW": "0",
"fanv2SetRotationDirectionCCW": "0",
"fanv2GetRotationSpeed": "0",
"fanv2SetRotationSpeed": "0"
}
]
Filter Maintenance Accessory Configuration
🚧 In HomeKit Accessory Protocol Specification available but currently not supported by the Home-App!
Name |
Value |
Required |
Option for |
Notes |
filterChangeIndication |
"V120.0" |
yes* |
"filterMaintenance" |
Filter Maintenance Get Filter Change Indication - Mn or Vn.n |
filterLifeLevel |
"0" |
no* |
"filterMaintenance" |
Filter Maintenance Get Filter Life Level - "0" or a valid LOGO! Address (AMn or VWn) |
filterResetFilterIndication |
"0" |
no* |
"filterMaintenance" |
Filter Maintenance Set Reset Filter Indication - "0" or a valid LOGO! Address (Mn or Vn.n) |
"accessories": [
{
"accessory": "Logo-TS",
"name": "Filter Maintenance ModBus",
"interface": "modbus",
"ip": "10.0.0.100",
"port": 505,
"type": "filterMaintenance",
"filterChangeIndication": "V120.0",
"filterLifeLevel": "0",
"filterResetFilterIndication": "0"
},
{
"accessory": "Logo-TS",
"name": "Filter Maintenance Snap7",
"interface": "snap7",
"ip": "10.0.0.200",
"logoType": "0BA7",
"localTSAP": "0x1200",
"remoteTSAP": "0x2200",
"type": "filterMaintenance",
"filterChangeIndication": "V120.0",
"filterLifeLevel": "0",
"filterResetFilterIndication": "0"
}
]
Ventilation Accessory Configuration
⚡ Fan Accessory + Filter Maintenance Accessory
😎 Not in HomeKit Accessory Protocol Specification available but supported by the Home-App!
Name |
Value |
Required |
Option for |
Notes |
ventilationGetOn |
"V130.0" |
yes* |
"ventilation" |
Ventilation Get On - Mn or Vn.n |
ventilationSetOn |
"V130.1" |
yes* |
"ventilation" |
Ventilation Set On to On - Mn or Vn.n |
ventilationSetOff |
"V130.2" |
yes* |
"ventilation" |
Ventilation Set On to Off - Mn or Vn.n |
ventilationGetRotationDirection |
"0" |
no* |
"ventilation" |
Ventilation Get Rotation Direction - "0" or a valid LOGO! Address (Mn or Vn.n) |
ventilationSetRotationDirectionCW |
"0" |
no* |
"ventilation" |
Ventilation Set Rotation Direction to Clockwise - "0" or a valid LOGO! Address (Mn or Vn.n) |
ventilationSetRotationDirectionCCW |
"0" |
no* |
"ventilation" |
Ventilation Set Rotation Direction to Counter Clockwise - "0" or a valid LOGO! Address (Mn or Vn.n) |
ventilationGetRotationSpeed |
"0" |
no* |
"ventilation" |
Ventilation Get Rotation Speed - "0" or a valid LOGO! Address (AMn or VWn) |
ventilationSetRotationSpeed |
"0" |
no* |
"ventilation" |
Ventilation Set Rotation Speed - "0" or a valid LOGO! Address (AMn or VWn) |
ventilationGetFilterChangeIndication |
"V120.0" |
yes* |
"ventilation" |
Ventilation Get Filter Change Indication - Mn or Vn.n |
ventilationGetFilterLifeLevel |
"0" |
no* |
"ventilation" |
Ventilation Get Filter Life Level - "0" or a valid LOGO! Address (AMn or VWn) |
ventilationSetResetFilterIndication |
"0" |
no* |
"ventilation" |
Ventilation Set Reset Filter Indication - "0" or a valid LOGO! Address (Mn or Vn.n) |
"accessories": [
{
"accessory": "Logo-TS",
"name": "Ventilation ModBus",
"interface": "modbus",
"ip": "10.0.0.100",
"port": 505,
"type": "ventilation",
"ventilationGetOn": "V130.0",
"ventilationSetOn": "V130.1",
"ventilationSetOff": "V130.2",
"ventilationGetRotationDirection": "0",
"ventilationSetRotationDirectionCW": "0",
"ventilationSetRotationDirectionCCW": "0",
"ventilationGetRotationSpeed": "0",
"ventilationSetRotationSpeed": "0",
"ventilationGetFilterChangeIndication": "V120.0",
"ventilationGetFilterLifeLevel": "0",
"ventilationSetResetFilterIndication": "0"
},
{
"accessory": "Logo-TS",
"name": "Ventilation Snap7",
"interface": "snap7",
"ip": "10.0.0.200",
"logoType": "0BA7",
"localTSAP": "0x1200",
"remoteTSAP": "0x2200",
"type": "ventilation",
"ventilationGetOn": "V130.0",
"ventilationSetOn": "V130.1",
"ventilationSetOff": "V130.2",
"ventilationGetRotationDirection": "0",
"ventilationSetRotationDirectionCW": "0",
"ventilationSetRotationDirectionCCW": "0",
"ventilationGetRotationSpeed": "0",
"ventilationSetRotationSpeed": "0",
"ventilationGetFilterChangeIndication": "V120.0",
"ventilationGetFilterLifeLevel": "0",
"ventilationSetResetFilterIndication": "0"
}
]
Light Sensor Accessory Configuration
Name |
Value |
Required |
Option for |
Notes |
lightLevel |
"AM3" |
yes* |
"lightSensor" |
Light Sensor for Current Ambient Light Level in Lux |
lightAsLux |
0 |
no |
"lightSensor" |
Light Level As Lux, 1 for calculat level from lightAsLuxIn... and lightAsLuxOut...
|
lightLDRLevel |
0 |
no |
"lightSensor" |
Light Level As LDR Level, 1 for calculat level from lightLDRLevelParts
|
lightAsLuxInMin |
0 |
no |
"lightSensor" |
Min Light Sensor Level from LOGO! |
lightAsLuxInMax |
1000 |
no |
"lightSensor" |
Max Light Sensor Level from LOGO! |
lightAsLuxOutMin |
0 |
no |
"lightSensor" |
Min Lux Level to display |
lightAsLuxOutMax |
65535 |
no |
"lightSensor" |
Max Lux Level to display |
lightLDRLevelParts |
3 |
no |
"lightSensor" |
Indicates how many formula parts the lux value is calculated. [1, 2, 3] more information about the light sensor
|
If lightAsLux
is 0
and lightLDRLevel
is 0
than this Light Sensor Accessory simply shows the value of the LOGO!
"accessories": [
{
"accessory": "Logo-TS",
"name": "Light Sensor (directly)",
"interface": "modbus",
"ip": "10.0.0.100",
"port": 505,
"updateInterval": 30000,
"type": "lightSensor",
"lightLevel": "AM3"
},
{
"accessory": "Logo-TS",
"name": "Light Sensor (0-10V lux sensor)",
"interface": "modbus",
"ip": "10.0.0.100",
"port": 505,
"updateInterval": 30000,
"type": "lightSensor",
"lightLevel": "AM3",
"lightAsLux": 1
},
{
"accessory": "Logo-TS",
"name": "Light Sensor (0-10V LDR sensor)",
"interface": "modbus",
"ip": "10.0.0.100",
"port": 505,
"updateInterval": 30000,
"type": "lightSensor",
"lightLevel": "AM3",
"lightLDRLevel": 1
}
]
Motion Sensor Accessory Configuration
Name |
Value |
Required |
Option for |
Notes |
motionDetected |
"M9" |
yes* |
"motionSensor" |
Motion Sensor |
"accessories": [
{
"accessory": "Logo-TS",
"name": "Motion Sensor",
"interface": "modbus",
"ip": "10.0.0.100",
"port": 505,
"updateInterval": 30000,
"type": "motionSensor",
"motionDetected": "M9"
}
]
Contact Sensor Accessory Configuration
Name |
Value |
Required |
Option for |
Notes |
contactDetected |
"M15" |
yes* |
"contactSensor" |
Contact Sensor |
"accessories": [
{
"accessory": "Logo-TS",
"name": "Contact Sensor",
"interface": "modbus",
"ip": "10.0.0.100",
"port": 505,
"updateInterval": 30000,
"type": "contactSensor",
"contactDetected": "M15"
}
]
Smoke Sensor Accessory Configuration
Name |
Value |
Required |
Option for |
Notes |
smokeDetected |
"M12" |
yes* |
"smokeSensor" |
Smoke Sensor |
"accessories": [
{
"accessory": "Logo-TS",
"name": "Smoke Sensor",
"interface": "modbus",
"ip": "10.0.0.100",
"port": 505,
"updateInterval": 30000,
"type": "smokeSensor",
"smokeDetected": "M12"
}
]
Temperature Sensor Accessory Configuration
Name |
Value |
Required |
Option for |
Notes |
temperature |
"AM2" |
yes* |
"temperatureSensor" |
Temperature Sensor for Current Temperature in °C (0°C - 100°C!!, a value of 105 is 10.5°C) |
"accessories": [
{
"accessory": "Logo-TS",
"name": "Temperature Sensor",
"interface": "modbus",
"ip": "10.0.0.100",
"port": 505,
"updateInterval": 30000,
"type": "temperatureSensor",
"temperature": "AM2"
}
]
Humidity Sensor Accessory Configuration
Name |
Value |
Required |
Option for |
Notes |
humidity |
"AM1" |
yes* |
"humiditySensor" |
Humidity Sensor for Current Relative Humidity in % |
"accessories": [
{
"accessory": "Logo-TS",
"name": "Humidity Sensor",
"interface": "modbus",
"ip": "10.0.0.100",
"port": 505,
"updateInterval": 30000,
"type": "humiditySensor",
"humidity": "AM1"
}
]
Carbon Dioxide Sensor Accessory Configuration
Name |
Value |
Required |
Option for |
Notes |
carbonDioxideLevel |
"AM3" |
yes* |
"carbonDioxideSensor" |
Carbon Dioxide Sensor for Carbon Dioxide Level in ppm |
carbonDioxideLimit |
1000 |
yes* |
"carbonDioxideSensor" |
Carbon Dioxide Sensor for Carbon Dioxide Peak Level in ppm |
"accessories": [
{
"accessory": "Logo-TS",
"name": "Carbon Dioxide Sensor",
"interface": "modbus",
"ip": "10.0.0.100",
"port": 505,
"updateInterval": 30000,
"type": "carbonDioxideSensor",
"carbonDioxideLevel": "AM3",
"carbonDioxideLimit": 1000
}
]
Air Quality Sensor Accessory Configuration
Name |
Value |
Required |
Option for |
Notes |
carbonDioxideLevel |
"AM3" |
yes* |
"airQualitySensor" |
Air Quality Sensor for Air Quality (Carbon Dioxide Level in ppm) |
"accessories": [
{
"accessory": "Logo-TS",
"name": "Air Quality Sensor",
"interface": "modbus",
"ip": "10.0.0.100",
"port": 505,
"updateInterval": 30000,
"type": "airQualitySensor",
"carbonDioxideLevel": "AM3"
}
]
Required: yes* - means that this parameter is only required for this particular accessory!
Required: no* - means if no valid LOGO address is specified for this parameter, this characteristic returns the specified value or is deactivated in the accessory!
The plugin that this one is based on: homebridge-tesla.
You can also view the full list of supported HomeKit Services and Characteristics in the HAP-NodeJS protocol repository.
Test Homebridge-Logo-TS
- Download or clone Homebridge-Logo-TS.
- Install:
$ npm install
- Build:
$ npm run build
- Run:
$ /usr/local/bin/homebridge -D -P ~/Homebridge-Logo-TS/