Use a Siemens LOGO! PLC for switch on whatever you want.
Communicate with LOGO! over Snap7 or Modbus.

Type of Accessory:

Type of Sensor Accessory:

Special Functions:

Examples:

Installation

  1. Install homebridge using instruction from: Homebridge WiKi
  2. Install this plugin in your homebridge
  3. Update your configuration file with code like the sample below

Thanks to

  • Tellicious for:
    • Adding logging to the Eve app.
    • Integrated valve as sub-accessory of IrrigationSystem.
    • His Bugfix to avoid memory leak.

Special thanks to

  • Davide Nardella for Snap7
  • Fabio Riva for Napi-Snap7. And for allowing me to improve his plugin.
  • Mathias Küsel for Node-Snap7 (was used until v1.3.8)

Known issues

  • The plugin cannot be configured with the Config UI. (The settings are too complex.)

Platform Main Configuration Parameters

Name Value Required Notes
platform "LogoPlatform" yes Must be set to "LogoPlatform".
name (custom) yes Name of platform that will not appear in homekit app.
interface "modbus" or "snap7" no Interface for communication, default is: "modbus".
ip "10.0.0.100" yes Must be set to the IP of your LOGO!.
port 502 no (ModBus) Must be set to the Modbus Port of your LOGO!, default is: 502.
logoType "0BA7" or ... no (Snap7) Must be set to the Type of your LOGO, default is: "0BA7".
localTSAP "0x1200" no (Snap7) Must be set to the local TSAP of your LOGO!, default is: "0x1200".
remoteTSAP "0x2200" no (Snap7) Must be set to the remote TSAP of your LOGO!, default is: "0x2200".
queueInterval 100 ... 1000 no Interval to send queries from Plugin to LOGO!, in milliseconds, default is: 100.
queueSize 100 ... 1000 no Number of items to be hold in send/receive queue, default is: 100.
updateInterval 0 ... ∞ no Auto Update Interval in milliseconds, 0 = Off
debugMsgLog 0 or 1 no Displays messages of all accessories in the log, default is: 0.
retryCount 0 ... ∞ no Retry count for sending the queries messages, default is: 5.
pushButton 0 or 1 no If e.g. the network input in the LOGO! a hardware button on the LOGO! simulated, default is: 0. (For all Accessories.)
loggerType "influxDB" or "fakegato" no Activates Logging, default is: "none".
loggerInterval 300000 no Logging Interval in milliseconds, default is: 300000 (5min)
influxDBUrl "http://10.0.0.99:8086" no (InfluxDB) IP-Address and Port for InfluxDB
influxDBToken "API Token" no (InfluxDB) InfluxDB API token
influxDBOrg "Org" no (InfluxDB) InfluxDB organization ID
influxDBBucket "Bucket" no (InfluxDB) InfluxDB bucket name
parentAccessory (custom) no Parent accessory name, needed to create this accessory as a sub-accessory of an other accessory. Not for Valve, IrrigationSystem and Other

Device Main Configuration Parameters

Name Value Required Notes
name (custom) yes Name of accessory that will appear in homekit app.
type "switch" or ... yes Type of Accessory: "switch", "lightbulb", "blind", "window", "garagedoor", "thermostat", "irrigationSystem", "valve", "fan", "filterMaintenance", "outlet", "other" or Type of Sensor Accessory: "lightSensor", "motionSensor", "contactSensor", "smokeSensor", "temperatureSensor", "humiditySensor", "carbonDioxideSensor", "airQualitySensor"
debugMsgLog 0 or 1 no Displays messages of this accessory in the log, default is: 0.
pushButton 0 or 1 no If e.g. the network input in the LOGO! a hardware button on the LOGO! simulated, default is: 0. (Only for this Accessory.)
logging 0 or 1 no Activates Logging, default is: 0. (Only for this Accessory.)
"platforms": [
    {
        "platform": "LogoPlatform",
        "name": "Logo 1",
        "ip": "10.0.0.100",
        "port": 505,
        "updateInterval": 10000,
        "debugMsgLog": 1,
        "pushButton": 1,
        "devices": [
            {
                "name": "Accessory Name 1",
                "type": "...",
                ...
            },
            {
                "name": "Accessory Name 2",
                "type": "...",
                ...
            }
        ]
    },
    {
        "platform": "LogoPlatform",
        "name": "Logo 2",
        "interface": "snap7",
        "ip": "10.0.0.200",
        "logoType": "0BA8",
        "localTSAP": "0x4200",
        "remoteTSAP": "0x4300",
        "updateInterval": 10000,
        "debugMsgLog": 1,
        "pushButton": 1,
        "devices": [
            {
                "name": "Accessory Name 3",
                "type": "...",
                ...
            },
            {
                "name": "Accessory Name 4",
                "type": "...",
                ...
            }
        ]
    }
]

Switch Configuration

Name Value Required Option for Notes
switchGet "Q1" yes* "switch" Switch Get - Qn, Mn or Vn.n
switchSetOn "V1.0" yes* "switch" Switch Set On - Mn or Vn.n
switchSetOff "V1.1" yes* "switch" Switch Set Off - Mn or Vn.n
{
    "name": "Q1",
    "type": "switch",
    "switchGet": "Q1",
    "switchSetOn": "V1.0",
    "switchSetOff": "V1.1"
}

Lightbulb Configuration

Name Value Required Option for Notes
lightbulbGet "Q4" yes* "lightbulb" lightbulb Get - Qn, Mn or Vn.n
lightbulbSetOn "V7.0" yes* "lightbulb" Lightbulb Set On - Mn or Vn.n
lightbulbSetOff "V7.1" yes* "lightbulb" Lightbulb Set Off - Mn or Vn.n
lightbulbSetBrightness "VW70" no* "lightbulb" Lightbulb Set Brightness - AMn or VWn
lightbulbGetBrightness "VW72" no* "lightbulb" Lightbulb Get Brightness - AMn or VWn
{
    "name": "Q1",
    "type": "lightbulb",
    "lightbulbGet": "Q1",
    "lightbulbSetOn": "V1.0",
    "lightbulbSetOff": "V1.1"
},
{
    "name": "Q4",
    "type": "lightbulb",
    "lightbulbGet": "Q4",
    "lightbulbSetOn": "V7.0",
    "lightbulbSetOff": "V7.1",
    "lightbulbSetBrightness": "VW70",
    "lightbulbGetBrightness": "VW72"
}

Blind Configuration

Name Value Required Option for Notes
blindSetTargetPos "VW26" yes* "blind" Blind Set Target Pos - AMn or VWn
blindGetTargetPos "VW28" yes* "blind" Blind Get Target Pos - AMn or VWn
blindGetPos "VW28" yes* "blind" Blind Get Pos - AMn or VWn
blindGetState "VW30" yes* "blind" Blind Get State - AMn or VWn
blindConvertValue 0 or 1 no* "blind" Convert LOGO! values in to HomeKit values.
{
    "name": "Item-6",
    "type": "blind",
    "blindConvertValue": 1,
    "blindSetTargetPos": "VW26",
    "blindGetTargetPos": "VW28",
    "blindGetPos": "VW28",
    "blindGetState": "VW30"
}

Window Configuration

Name Value Required Option for Notes
windowSetTargetPos "VW32" yes* "window" Window Set Target Pos - AMn or VWn
windowGetTargetPos "VW34" yes* "window" Window Get Target Pos - AMn or VWn
windowGetPos "VW34" yes* "window" Window Get Pos - AMn or VWn
windowSetState "VW36" yes* "window" Window Get State - AMn or VWn
windowConvertValue 0 or 1 no* "window" Convert LOGO! values in to HomeKit values.
{
    "name": "Item-7",
    "type": "window",
    "windowConvertValue": 1,
    "windowSetTargetPos": "VW32",
    "windowGetTargetPos": "VW34",
    "windowGetPos": "VW34",
    "windowGetState": "VW36"
}

Garage Door Configuration

Name Value Required Option for Notes
garagedoorGetState "VW40" or "M9" yes* "garagedoor" Garagedoor Get State - Analog AMn or VWn (0 = Open; 1 = Closed; 2 = Opening; 3 = Closing; 4 = Stopped) Digital Mn or Vn.n (0 = Closed; 1 = Open)
garagedoorGetTargetState "VW40" or "M9" yes* "garagedoor" Garagedoor Get Target State - Analog AMn or VWn (0 = Open; 1 = Closed) Digital Mn or Vn.n (0 = Closed; 1 = Open)
garagedoorSetTargetState "VW38" yes* "garagedoor" Garagedoor Set Target State - AMn or VWn (0 = Open; 1 = Closed)
garagedoorObstruction "V3.0" no* "garagedoor" Garagedoor Obstruction Detected - Mn, Vn.n
{
    "name": "Item-8",
    "type": "garagedoor",
    "garagedoorGetState": "VW40",
    "garagedoorGetTargetState": "VW40",
    "garagedoorSetTargetState": "VW38",
    "garagedoorObstruction": "V3.0"
}

Thermostat Configuration

Name Value Required Option for Notes
thermostatGetHCState "VW42" yes* "thermostat" Thermostat Get Heating Cooling State - AMn or VWn
thermostatGetTargetHCState "VW44" yes* "thermostat" Thermostat Get Target Heating Cooling State - AMn or VWn
thermostatSetTargetHCState "VW46" yes* "thermostat" Thermostat Set Target Heating Cooling State - AMn or VWn
thermostatGetTemp "VW48" yes* "thermostat" Thermostat Get Temperature - AMn or VWn - Current Temperature in °C (-270°C - 100°C!!)
thermostatGetTargetTemp "VW50" yes* "thermostat" Thermostat Get Target Temperature - AMn or VWn - Current Temperature in °C (10°C - 38°C!!)
thermostatSetTargetTemp "VW52" yes* "thermostat" Thermostat Set Target Temperature - AMn or VWn
thermostatTempDisplayUnits 0 or 1 yes* "thermostat" Temperature Display Units - Celsius = 0; Fahrenheit = 1;
thermostatConvertValue 0 or 1 no* "thermostat" Convert Int in Float, default is: 0. (235 / 10 == 23.5°C)
{
    "name": "Item-9",
    "type": "thermostat",
    "thermostatGetHCState": "VW42",
    "thermostatGetTargetHCState": "VW44",
    "thermostatSetTargetHCState": "VW46",
    "thermostatGetTemp": "VW48",
    "thermostatGetTargetTemp": "VW50",
    "thermostatSetTargetTemp": "VW52",
    "thermostatTempDisplayUnits": 0,
    "thermostatConvertValue": 1
}

Irrigation System Configuration

Name Value Required Option for Notes
irrigationSystemGetActive "V4.0" yes* "irrigationSystem" Irrigation System Get Active - Mn or Vn.n
irrigationSystemSetActiveOn "V4.1" yes* "irrigationSystem" Irrigation System Set Active to On - Mn or Vn.n
irrigationSystemSetActiveOff "V4.2" yes* "irrigationSystem" Irrigation System Set Active to Off - Mn or Vn.n
irrigationSystemGetProgramMode "VW54" yes* "irrigationSystem" Irrigation System Get Program Mode - AMn or VWn - (0 - No Program scheduled; 1 - Program scheduled; 2 - Program scheduled manual Mode)
irrigationSystemGetInUse "V4.3" yes* "irrigationSystem" Irrigation System Get In Use - Mn or Vn.n
irrigationSystemGetRemainingDuration "VW56" no* "irrigationSystem" Irrigation System Get Remaining Duration - AMn or VWn
irrigationSystemGetWaterLevel "VW58" no* "irrigationSystem" Irrigation System Get Water Level % - AMn or VWn
irrigationSystemAutoUpdate 1 no* "irrigationSystem" Auto update of Irrigation System based on valves sub-accessories. If set irrigationSystemGetActive and irrigationSystemGetInUse are not necessary and can remain unset
{
    "name": "Item-10",
    "type": "irrigationSystem",
    "irrigationSystemGetActive": "V4.0",
    "irrigationSystemSetActiveOn": "V4.1",
    "irrigationSystemSetActiveOff": "V4.2",
    "irrigationSystemGetProgramMode": "VW54",
    "irrigationSystemGetInUse": "V4.3",
    "irrigationSystemGetRemainingDuration": "VW56",
    "irrigationSystemGetWaterLevel": "VW58"
}

{
    "name": "Item-10",
    "type": "irrigationSystem",
    "irrigationSystemSetActiveOn": "V4.1",
    "irrigationSystemSetActiveOff": "V4.2",
    "irrigationSystemGetProgramMode": "VW54",
    "irrigationSystemGetRemainingDuration": "VW56",
    "irrigationSystemGetWaterLevel": "VW58",
    "irrigationSystemAutoUpdate": 1
}

Valve Configuration

Name Value Required Option for Notes
valveGetActive "V5.0" yes* "valve" Valve Get Active - Mn or Vn.n
valveSetActiveOn "V5.1" yes* "valve" Valve Set Active to On - Mn or Vn.n
valveSetActiveOff "V5.2" yes* "valve" Valve Set Active to Off - Mn or Vn.n
valveGetInUse "V5.3" yes* "valve" Valve Get In Use - Mn or Vn.n
valveType 0 yes* "valve" Valve Type - Generic Valve = 0, Irrigation = 1, Shower Head = 2, Water Faucet = 3. Defaults to 1 when valveParentIrrigationSystem is set
valveSetDuration "VW56" no* "valve" Valve Set Duration - AMn or VWn - Value in Seconds (0 - 3600 sec)
valveGetDuration "VW56" no* "valve" Valve Get Duration - AMn or VWn - Value in Seconds (0 - 3600 sec)
valveGetRemainingDuration "VW58" no* "valve" Valve Get Remaining Duration - AMn or VWn - Value in Seconds (0 - 3600 sec)
valveSetIsConfiguredOn "V5.4" no* "valve" Valve Set Is Configured / Enabled On - Mn or Vn.n
valveSetIsConfiguredOff "V5.5" no* "valve" Valve Set Is Configured / Enabled Off - Mn or Vn.n
valveGetIsConfigured "V5.6" no* "valve" Valve Get Is Configured / Enabled - Mn or Vn.n
valveParentIrrigationSystem "Item-10" no* "valve" Valve parent Irrigation System accessory name, needed to create the valve as a sub-accessory of an Irrigation System
valveZone 1 no* "valve" Valve zone, needed when valve is part of an Irrigation System accessory
  • Item-11-A: Valve as child from a Irrigation System (Item-10)
  • Item-11-B: Valve without IsConfigured characteristic
  • Item-11-C: Valve with IsConfigured characteristic
  • Item-11-D: Valve as minimum without SetDuration and IsConfigured
{
    "name": "Item-11-A",
    "type": "valve",
    "valveGetActive": "V5.0",
    "valveSetActiveOn": "V5.1",
    "valveSetActiveOff": "V5.2",
    "valveGetInUse": "V5.3",
    "valveType": 1,
    "valveSetDuration": "VW56",
    "valveGetDuration": "VW56",
    "valveGetRemainingDuration": "VW58",
    "valveParentIrrigationSystem": "Item-10",
    "valveZone": 1
}
{
    "name": "Item-11-B",
    "type": "valve",
    "valveGetActive": "V5.0",
    "valveSetActiveOn": "V5.1",
    "valveSetActiveOff": "V5.2",
    "valveGetInUse": "V5.3",
    "valveType": 1,
    "valveSetDuration": "VW56",
    "valveGetDuration": "VW56",
    "valveGetRemainingDuration": "VW58"
}
{
    "name": "Item-11-C",
    "type": "valve",
    "valveGetActive": "V5.0",
    "valveSetActiveOn": "V5.1",
    "valveSetActiveOff": "V5.2",
    "valveGetInUse": "V5.3",
    "valveType": 1,
    "valveSetDuration": "VW56",
    "valveGetDuration": "VW56",
    "valveGetRemainingDuration": "VW58",
    "valveSetIsConfiguredOn": "V5.4",
    "valveSetIsConfiguredOff": "V5.5",
    "valveGetIsConfigured": "V5.6"
}
{
    "name": "Item-11-D",
    "type": "valve",
    "valveGetActive": "V5.3",
    "valveSetActiveOn": "V5.1",
    "valveSetActiveOff": "V5.1",
    "valveGetInUse": "V5.3",
    "valveType": 1,
    "pushButton": 0
}

Fan Configuration

Name Value Required Option for Notes
fanGet "V6.0" yes* "fan" Fan Get - Mn or Vn.n
fanSetOn "V6.1" yes* "fan" Fan Set On - Mn or Vn.n
fanSetOff "V6.2" yes* "fan" Fan Set Off - Mn or Vn.n
fanGetRotationDirection "V6.3" no* "fan" Fan Get Rotation Direction - Mn or Vn.n
fanSetRotationDirectionCW "V6.4" no* "fan" Fan Set Rotation Direction to Clockwise - Mn or Vn.n
fanSetRotationDirectionCCW "V6.5" no* "fan" Fan Set Rotation Direction to Counter Clockwise - Mn or Vn.n
fanGetRotationSpeed "VW60" no* "fan" Fan Get Rotation Speed - AMn or VWn
fanSetRotationSpeed "VW62" no* "fan" Fan Set Rotation Speed - AMn or VWn
{
    "name": "Item-12",
    "type": "fan",
    "fanGet": "V6.0",
    "fanSetOn": "V6.1",
    "fanSetOff": "V6.2",
    "fanGetRotationDirection": "V6.3",
    "fanSetRotationDirectionCW": "V6.4",
    "fanSetRotationDirectionCCW": "V6.5",
    "fanGetRotationSpeed": "VW60",
    "fanSetRotationSpeed": "VW62"
}

Filter Maintenance Configuration

The Home-App only supports this accessory as an additional feature of a dehumidifier, for example.

Name Value Required Option for Notes
filterChangeIndication "V7.0" yes* "filterMaintenance" Filter Maintenance Get Filter Change Indication - Mn or Vn.n
filterLifeLevel "VW64" no* "filterMaintenance" Filter Maintenance Get Filter Life Level - AMn or VWn
filterResetFilterIndication "V7.1" no* "filterMaintenance" Filter Maintenance Set Reset Filter Indication - Mn or Vn.n
{
    "name": "Item-13",
    "type": "filterMaintenance",
    "filterChangeIndication": "V7.0",
    "filterLifeLevel": "VW64",
    "filterResetFilterIndication": "V7.1"
}

Outlet Configuration

Name Value Required Option for Notes
outletGet "Q1" yes* "outlet" Outlet Get - Qn, Mn or Vn.n
outletSetOn "V1.0" yes* "outlet" Outlet Set On - Mn or Vn.n
outletSetOff "V1.1" yes* "outlet" Outlet Set Off - Mn or Vn.n
outletGetInUse "V1.2" yes* "outlet" Outlet Get In Use - Qn, Mn or Vn.n
{
    "name": "Q1",
    "type": "outlet",
    "outletGet": "Q1",
    "outletSetOn": "V1.0",
    "outletSetOff": "V1.1"
}

Other Configuration

This accessory can contain other accessories, but does not respond to tapping to turn it on or off. It opens a detailed view of the sub accessories.

Name Value Required Option for Notes
name (custom) yes Name of accessory that will appear in homekit app.
type "other" yes Type of Accessory: "other"
{
    "name": "Ventilation",
    "type": "other"
},
{
    "name": "Level 1",
    "type": "switch",
    "switchGet": "Q3",
    "switchSetOn": "V3.2",
    "switchSetOff": "V4.2",
    "parentAccessory": "Ventilation"
},
{
    "name": "Level 2",
    "type": "switch",
    "switchGet": "Q4",
    "switchSetOn": "V3.3",
    "switchSetOff": "V4.3",
    "parentAccessory": "Ventilation"
},
{
    "name": "Automatic",
    "type": "switch",
    "switchGet": "M16",
    "switchSetOn": "V3.4",
    "switchSetOff": "V4.4",
    "parentAccessory": "Ventilation"
},
{
    "name": "Supply Air",
    "type": "temperatureSensor",
    "convertValue": 1,
    "temperature": "AM5",
    "parentAccessory": "Ventilation"
},
{
    "name": "Exhaust Air",
    "type": "temperatureSensor",
    "convertValue": 1,
    "temperature": "AM6",
    "parentAccessory": "Ventilation"
}

other

Light Sensor Configuration

Name Value Required Option for Notes
light "VW66" yes* "lightSensor" Light Sensor for Current Ambient Light Level in Lux
{
    "name": "Sensor-1",
    "type": "lightSensor",
    "light": "VW66"
}

Motion Sensor Configuration

Name Value Required Option for Notes
motion "V8.0" yes* "motionSensor" Motion Sensor
{
    "name": "Sensor-2",
    "type": "motionSensor",
    "motion": "V8.0"
}

Contact Sensor Configuration

Name Value Required Option for Notes
contact "V8.1" yes* "contactSensor" Contact Sensor
{
    "name": "Sensor-3",
    "type": "contactSensor",
    "contact": "V8.1"
}

Smoke Sensor Configuration

Name Value Required Option for Notes
smoke "V8.2" yes* "smokeSensor" Smoke Sensor
{
    "name": "Sensor-4",
    "type": "smokeSensor",
    "smoke": "V8.2"
}

Temperature Sensor Configuration

Name Value Required Option for Notes
temperature "VW68" yes* "temperatureSensor" Temperature Sensor for Current Temperature in °C (-270°C - 100°C!!)
convertValue 0 or 1 no* "temperatureSensor" Convert Int in Float, default is: 0. (235 / 10 == 23.5°C)
{
    "name": "Sensor-5",
    "type": "temperatureSensor",
    "convertValue": 1,
    "temperature": "VW68"
}

Humidity Sensor Configuration

Name Value Required Option for Notes
humidity "VW70" yes* "humiditySensor" Humidity Sensor for Current Relative Humidity in %
convertValue 0 or 1 no* "humiditySensor" Convert Int in Float, default is: 0. (456 / 10 == 45.6%rH => 46%rH in Home App)
{
    "name": "Sensor-6",
    "type": "humiditySensor",
    "convertValue": 1,
    "humidity": "VW70"
}

Carbon Dioxide Sensor Configuration

Name Value Required Option for Notes
carbonDioxide "V9.0" yes* "carbonDioxideSensor" Carbon Dioxide
carbonDioxideLevel "VW72" no* "carbonDioxideSensor" Carbon Dioxide Level in ppm
carbonDioxidePeakLevel "VW74" no* "carbonDioxideSensor" Carbon Dioxide Peak Level in ppm
{
    "name": "Sensor-7",
    "type": "carbonDioxideSensor",
    "carbonDioxide": "V9.0",
    "carbonDioxideLevel": "VW72",
    "carbonDioxidePeakLevel": "VW74"
}

Air Quality Sensor Configuration

Name Value Required Option for Notes
airQuality "VW76" yes* "airQualitySensor" Air Quality (0 - 5)
  • 0 - Unknown
  • 1 - Excellent - CO2 < 800ppm (IDA 1)
  • 2 - Good - CO2 = 800 - 1000ppm (IDA 2)
  • 3 - Fair - CO2 = 1000 - 1400ppm (IDA 3)
  • 4 - Inferior - CO2 = 1400 - 1800ppm (IDA 4)
  • 5 - Poor - CO2 > 1800ppm
{
    "name": "Sensor-8",
    "type": "airQualitySensor",
    "airQuality": "VW76"
}

Leak Sensor Configuration

Name Value Required Option for Notes
leak "V9.1" yes* "leakSensor" Leak Sensor
waterLevel "VW78" no* "leakSensor" Water Level in %
{
    "name": "Sensor-9",
    "type": "leakSensor",
    "leak": "V9.1",
    "waterLevel": "VW78"
}

Logging to InfluxDB or Eve App

Type Characteristic InfluxDB Eve App
Switch On yes yes
Lightbulb On
Brightness
yes
yes
yes
no
Blind CurrentPosition
PositionState
TargetPosition
yes
yes
yes
no
no
no
Window CurrentPosition
PositionState
TargetPosition
yes
yes
yes
no
no
no
Garage Door CurrentDoorState
TargetDoorState
ObstructionDetected
yes
yes
yes
no
no
no
Thermostat CurrentHeatingCoolingState
TargetHeatingCoolingState
CurrentTemperature
TargetTemperature
yes
yes
yes
yes
no
no
yes
yes
Irrigation System Active
ProgramMode
InUse
RemainingDuration
WaterLevel
yes
yes
yes
yes
yes
no
no
no
no
no
Valve Active
InUse
RemainingDuration
SetDuration
IsConfigured
yes
yes
yes
yes
yes
no
no
no
no
no
Fan On
RotationDirection
RotationSpeed
yes
yes
yes
no
no
no
Filter Maintenance FilterChangeIndication
FilterLifeLevel
ResetFilterIndication
yes
yes
yes
no
no
no
Outlet On
InUse
yes
yes
yes
no
Light Sensor CurrentAmbientLightLevel yes no
Motion Sensor MotionDetected yes yes
Contact Sensor ContactSensorState yes yes
Smoke Sensor SmokeDetected yes no
Temperature Sensor CurrentTemperature yes yes
Humidity Sensor CurrentRelativeHumidity yes yes
Carbon Dioxide Sensor CarbonDioxideDetected
CarbonDioxideLevel
CarbonDioxidePeakLevel
yes
yes
yes
no
yes
no
Air Quality Sensor AirQuality yes no
Leak Sensor LeakDetected
WaterLevel
yes
yes
no
no

Main Configuration

"platforms": [
        {
            "platform": "LogoPlatform",
            "name": "Logo 6",
            "ip": "10.0.0.100",
            "port": 502,
            "updateInterval": 10000,
            "debugMsgLog": 1,
            "pushButton": 1,
            "loggerType": "influxDB",
            "loggerInterval": 30000,
            "influxDBUrl": "http://10.0.0.99:8086",
            "influxDBToken": "qwertzuiopasdfghjklyxcvbnm1234567890",
            "influxDBOrg": "Org-Name",
            "influxDBBucket": "Bucket-Name",
            "devices": [
                {
                    "name": "Logo 6 - Q1",
                    "type": "switch",
                    "switchGet": "Q1",
                    "switchSetOn": "V1.0",
                    "switchSetOff": "V1.1",
                    "logging": 1
                },
                {
                    "name": "Logo 6 - Q2",
                    "type": "switch",
                    "switchGet": "Q2",
                    "switchSetOn": "V1.2",
                    "switchSetOff": "V1.3"
                },
                {
                    "name": "Logo 6 - Q3",
                    "type": "switch",
                    "switchGet": "Q3",
                    "switchSetOn": "V1.4",
                    "switchSetOff": "V1.5",
                    "logging": 1
                },
                {
                    "name": "Logo 6 - M1",
                    "type": "switch",
                    "switchGet": "M1",
                    "switchSetOn": "V1.6",
                    "switchSetOff": "V1.7"
                },
                {
                    "name": "Logo 6 - Q4",
                    "type": "lightbulb",
                    "lightbulbGet": "Q4",
                    "lightbulbSetOn": "V2.0",
                    "lightbulbSetOff": "V2.1",
                    "lightbulbSetBrightness": "VW20",
                    "lightbulbGetBrightness": "VW22",
                    "logging": 1
                }
            ]
        },
        {
            "platform": "LogoPlatform",
            "name": "Logo 7",
            "interface": "snap7",
            "ip": "10.0.0.101",
            "logoType": "0BA7",
            "localTSAP": "0x2200",
            "remoteTSAP": "0x2100",
            "updateInterval": 10000,
            "debugMsgLog": 1,
            "pushButton": 1,
            "retryCount": 5,
            "devices": [
                {
                    "name": "Logo 7 - Q1",
                    "type": "switch",
                    "switchGet": "Q1",
                    "switchSetOn": "V1.0",
                    "switchSetOff": "V1.1"
                },
                {
                    "name": "Logo 7 - Q2",
                    "type": "switch",
                    "switchGet": "Q2",
                    "switchSetOn": "V1.2",
                    "switchSetOff": "V1.3"
                },
                {
                    "name": "Logo 7 - Q3",
                    "type": "switch",
                    "switchGet": "Q3",
                    "switchSetOn": "V1.4",
                    "switchSetOff": "V1.5"
                },
                {
                    "name": "Logo 7 - M1",
                    "type": "switch",
                    "switchGet": "M1",
                    "switchSetOn": "V1.6",
                    "switchSetOff": "V1.7"
                },
                {
                    "name": "Logo 7 - Q4",
                    "type": "lightbulb",
                    "lightbulbGet": "Q4",
                    "lightbulbSetOn": "V2.0",
                    "lightbulbSetOff": "V2.1",
                    "lightbulbSetBrightness": "VW20",
                    "lightbulbGetBrightness": "VW22"
                }
            ]
        }
    ]

Type of your LOGO

Type Snap7 Webserver ModBus Cloud MemoryLayout LSC
"0BA7" yes no no no old 0BA7.Standard
"0BA8" yes yes no no new LOGO! 8 (0BA8.Standard)
"0BA0" yes yes yes no new LOGO! 8.1 & 8.2 (LOGO! 8.FS4)
"0BA1" yes yes yes yes new LOGO! 8.3

Required: yes* - means that this parameter is only required for this particular accessory!
Required: no* - means if no valid LOGO address is specified for this parameter, this characteristic returns the specified value or is deactivated in the accessory!

Test Homebridge-Logo-Platform

  1. Download or clone Homebridge-Logo-Platform.
  2. Install: $ npm install
  3. Build: $ npm run build
  4. Run: $ /usr/local/bin/homebridge -D -P ~/Homebridge-Logo-Platform/

Package Sidebar

Install

npm i homebridge-logo-platform

Weekly Downloads

121

Version

1.4.3

License

---

Unpacked Size

10.8 MB

Total Files

198

Last publish

Collaborators

  • sinclair81