homebridge-garagedoor-iologik

1.0.1 • Public • Published

homebridge-garagedoor-iologik

npm npm npm

Hörmann Supramatic garage door opener plugin for Homebridge.

Hörmann and Supramatic are trademarks owned by Hörmann KG Verkaufsgesellschaft.

Moxa and ioLogik are trademarks owned by Moxa Inc.

This plugin was developed for a Hörmann Supramatic garage door opener connected via a UAP1 (Universal Adapter Print) and a Moxa ioLogik E1214 remote Ethernet I/O server.

Installation

  1. Connect and configure the UAP1 and ioLogik E1214 (see wiring and configuration guide below).
  2. Install this plugin using: npm install -g homebridge-garagedoor-iologik
  3. Edit config.json and add a Garagedoor-ioLogik accessory for each garage door to be controlled (see example below).
  4. Run Homebridge.

Wiring

The Supramatic provides 24V DC power to the ioLogik E1214 via the UAP1. The power terminal block on the top panel of the ioLogik E1214 should be connected to the main terminal block in the UAP1 as follows:

ioLogik E1214 UAP1 Description
V+ 5 (24V) Power supply for ioLogik E1214
V- 20 (0V) Power supply for ioLogik E1214
GND Ground not connected to UAP1

The ioLogik E1214 main I/O channels terminal block is wired to the UAP1 as follows:

ioLogik E1214 UAP1 Description
COM 5 (24V) Common for DI channels
DI0 K01.8 DI-00 input: Door open
DI1 K02.8 DI-01 input: Door closed
DI2 - (not connected)
DI3 - (not connected)
DI4 - (not connected)
DI5 - (not connected)
GND 20 (0V) Ground for DI channels
R0_NO - (not connected)
R0_C - (not connected)
R1_NO - (not connected)
R1_C - (not connected)
R2_NO 15 (S2) DO-02 relay output: Go open
R2_C 20 (0V) DO-02 relay common: Go open
R3_NO 23 (S3) DO-02 relay output: Go partial open
R3_C 20 (0V) DO-02 relay common: Go partial open
R4_NO 17 (S4) DO-02 relay output: Go close
R4_C 20 (0V) DO-02 relay common: Go close
R5_NO 10 (S5) DO-02 relay output: Toggle light
R5_C 20 (0V) DO-02 relay common: Toggle light

The DI channels are connected to the UAP1 relays as dry contacts. The DO channels connect the UAP1 inputs to 0V when the relays are activated.

ioLogik Configuration

The ioLogik E1214 must be running firmware version 2.5 or later to support RESTful API. Ensure that the Enable Resful API option is enabled.

The DI channels should be configured as follows:

DI Channel Mode Filter Alias of Channel Alias of OFF Status Alias of ON Status
DI-00 DI 100ms Door is open Not open Open
DI-01 DI 100ms Door is closed Not closed Closed
DI-02 DI 100ms DI OFF ON
DI-03 DI 100ms DI OFF ON
DI-04 DI 100ms DI OFF ON
DI-05 DI 100ms DI OFF ON

The DO channels should be configured as follows:

DO Channel Mode OFF Width ON Width Pulse Count Alias of Channel Alias of OFF Status Alias of ON Status
DO-00 DO DO OFF ON
DO-01 DO DO OFF ON
DO-02 Pulse Output 1 (1.5s) 1 (1.5s) 1 Open Idle Go open
DO-03 Pulse Output 1 (1.5s) 1 (1.5s) 1 Partial open Idle Go partial open
DO-04 Pulse Output 1 (1.5s) 1 (1.5s) 1 Close Idle Go close
DO-05 Pulse Output 1 (1.5s) 1 (1.5s) 1 Light Idle Toggle light

Example config.json

{
    "accessories":
    [{
        "accessory":    "Garagedoor-ioLogik",
        "name":         "Bunker Door",
        "host":         "iologik-e1214"
    }]
}

Multiple accessories can be added to control different garage doors. They must be each given a unique name.

The host specifies how to reach the ioLogik E1214.

Notes

The following (non-default) timings are hardcoded in the plugin:

MENU 2 Switch-off delay Description
5 5 minutes Illumination during and after door movement
9 15 minutes Switched via radio/external button

License

ISC License (ISC)
Copyright © 2019 Alexander Thoukydides

Permission to use, copy, modify, and/or distribute this software for any purpose with or without fee is hereby granted, provided that the above copyright notice and this permission notice appear in all copies.

THE SOFTWARE IS PROVIDED "AS IS" AND THE AUTHOR DISCLAIMS ALL WARRANTIES WITH REGARD TO THIS SOFTWARE INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS. IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY SPECIAL, DIRECT, INDIRECT, OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS, WHETHER IN AN ACTION OF CONTRACT, NEGLIGENCE OR OTHER TORTIOUS ACTION, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THIS SOFTWARE.

Dependents (0)

Package Sidebar

Install

npm i homebridge-garagedoor-iologik

Weekly Downloads

6

Version

1.0.1

License

ISC

Unpacked Size

22.9 kB

Total Files

6

Last publish

Collaborators

  • thouky