ever-ups-adapter

2022.0.6 • Public • Published

EVER UPS Adapter


This module implements modified version of net-snmp as EVER is adding \x00 (NULL char) at the end of every response line.


Support matrix

Device Supported protocols
RT3000 XL SNMP (v1)

If you tested this adapter on another device, and it worked as should, please add PR with updated table above.


SNMP OID & variables list

OID Description
1.3.6.1.2.1.33.1.1.1.0 Manufacturer name
1.3.6.1.2.1.33.1.1.2.0 Model name
1.3.6.1.2.1.33.1.1.3.0 Device firmware version
1.3.6.1.2.1.33.1.1.4.0 Agent firmware version
1.3.6.1.2.1.33.1.1.5.0 Identification name
1.3.6.1.2.1.33.1.1.6.0 Output devices identification
1.3.6.1.2.1.33.1.2.1.0 Battery status
1.3.6.1.2.1.33.1.2.2.0 Seconds on battery
1.3.6.1.2.1.33.1.2.3.0 Estimated minutes remaining
1.3.6.1.2.1.33.1.2.4.0 Estimated battery percentage
1.3.6.1.2.1.33.1.2.5.0 Battery voltage
1.3.6.1.2.1.33.1.2.6.0 Battery current
1.3.6.1.2.1.33.1.2.7.0 Battery temperature
1.3.6.1.2.1.33.1.3.1.0 Count of time the input entered an out-of-tolerance condition
1.3.6.1.2.1.33.1.3.2.0 Utilized input lines number
1.3.6.1.2.1.33.1.4.1.0 Output source
1.3.6.1.2.1.33.1.4.2.0 Output frequency
1.3.6.1.2.1.33.1.4.3.0 Output lines number
1.3.6.1.2.1.33.1.5.1.0 Bypass frequency
1.3.6.1.2.1.33.1.5.2.0 Bypass lines number
1.3.6.1.2.1.33.1.6.1.0 Number of active alarm conditions
1.3.6.1.2.1.33.1.7.1.0 UPS test name
1.3.6.1.2.1.33.1.7.2.0 UPS test spin lock
1.3.6.1.2.1.33.1.7.3.0 UPS test diagnostics result
1.3.6.1.2.1.33.1.7.4.0 UPS test result detail
1.3.6.1.2.1.33.1.7.5.0 UPS test start time
1.3.6.1.2.1.33.1.7.6.0 UPS test elapsed time
1.3.6.1.2.1.33.1.8.1.0 UPS shutdown type
1.3.6.1.2.1.33.1.8.2.0 UPS shutdown after delay
1.3.6.1.2.1.33.1.8.3.0 UPS startup after delay
1.3.6.1.2.1.33.1.8.4.0 UPS reboot with duration
1.3.6.1.2.1.33.1.8.5.0 UPS auto restart
1.3.6.1.2.1.33.1.9.1.0 Nominal input voltage
1.3.6.1.2.1.33.1.9.2.0 Nominal input frequency
1.3.6.1.2.1.33.1.9.3.0 Nominal output voltage
1.3.6.1.2.1.33.1.9.4.0 Nominal output frequency
1.3.6.1.2.1.33.1.9.5.0 Nominal Volt-Amp rating
1.3.6.1.2.1.33.1.9.6.0 Nominal output power rating
1.3.6.1.2.1.33.1.9.7.0 Low battery alert condition of estimated minutes remaining
1.3.6.1.2.1.33.1.9.8.0 Status of audible alarm
1.3.6.1.2.1.33.1.9.9.0 Minimum input line voltage allowed to transfer to backup
1.3.6.1.2.1.33.1.9.10.0 Maximum input line voltage allowed to transfer to backup

Example input line table

OID Description
1.3.6.1.2.1.33.1.3.3.1.<index>.1 Input index
1.3.6.1.2.1.33.1.3.3.1.<index>.2 Input frequency
1.3.6.1.2.1.33.1.3.3.1.<index>.3 Input voltage
1.3.6.1.2.1.33.1.3.3.1.<index>.4 Input current
1.3.6.1.2.1.33.1.3.3.1.<index>.5 Input true power

Example output line table

OID Description
1.3.6.1.2.1.33.1.4.4.1.<index>.1 Output index
1.3.6.1.2.1.33.1.4.4.1.<index>.2 Output voltage
1.3.6.1.2.1.33.1.4.4.1.<index>.3 Output current
1.3.6.1.2.1.33.1.4.4.1.<index>.4 Output true power
1.3.6.1.2.1.33.1.4.4.1.<index>.5 Output load percentage

HTTP API Attributes List

Feature will come in future releases